- AutorIn
- Karen L. Rojas-Gómez Department of Aquatic Ecosystem Analysis, Helmholtz-Centre for Environmental Research – UFZ, Magdeburg, Germany#Technische Universität Dresden, Germany
- Martin BinderChair of Hydrogeology and Hydrochemistry, Institute of Geology, Technische Universität Bergakademie Freiberg, Freiberg, Germany#Department of Environmental Sciences, Applied and Environmental Geology, University of Basel, Basel, Switzerland
- Marc WaltherTechnische Universität Dresden, Germany
- Christian Engelmann
- Titel
- A parsimonious approach to predict regions affected by sewer-borne contaminants in urban aquifers
- Zitierfähige Url:
- https://nbn-resolving.org/urn:nbn:de:bsz:14-qucosa2-966106
- Quellenangabe
- Environmental Monitoring and Assessment
Erscheinungsjahr: 2023
Jahrgang: 195
E-ISSN: 1573-2959
Artikelnummer: 1517 - Erstveröffentlichung
- 2023
- Abstract (EN)
- Leaky urban drainage networks (UDNs) exfiltrating wastewater can contaminate aquifers. Detailed knowledge on spatiotemporal distributions of water-dissolved, sewer-borne contaminants in groundwater is essential to protect urban aquifers and to optimize monitoring systems. We evaluated the effect of UDN layouts on the spreading of sewer-borne contaminants in groundwater using a parsimonious approach. Due to the UDN’s long-term leakage behavior and the existence of non-degradable sewer-borne contaminants (equivalent to a conservative and constant contaminant source), we employed a concept of horizontal line sources to mimic the UDN layout. This does not require the consideration of bio-degradation processes or temporal delay and effectively bypasses the vadose zone, thus reducing computational requirements associated with a full simulation of leakages. We used a set of synthetic leakage scenarios which were generated using fractals and are based on a real-world UDN layout. We investigated the effects of typical leakage rates, varying groundwater flow directions, and UDN’s layouts on the shape of the contaminant plume, disregarding the resulted concentration. Leakage rates showed minimal effects on the total covered plume area, whereas 89% of the variance of the plume’s geometry is explained by both the UDN’s layout (e.g., length and level of complexity) and groundwater flow direction. We demonstrated the potential of applying this approach to identify possible locations of groundwater observation wells using a real UDN layout. This straightforward and parsimonious method can serve as an initial step to strategically identify optimal monitoring systems locations within urban aquifers, and to improve sewer asset management at city scale.
- Andere Ausgabe
- Link zum Artikel, der zuerst in der Zeitschrift „Environmental Monitoring and Assessment” im Verlag Springer erschienen ist.
DOI: 10.1007/s10661-023-12027-6 - Verweis
- Ergänzendes Material ist unter folgendem Link zu finden.
Link: https://link.springer.com/article/10.1007/s10661-023-12027-6#Sec19 - Freie Schlagwörter (EN)
- Groundwater monitoring, Risk area identifcation, Sewer leakage, Sewer network, Transport simulation
- Klassifikation (DDC)
- 333.7
- Verlag
- Springer, Dordrecht
- Förder- / Projektangaben
- Deutsche Forschungsgemeinschaft (DFG)
Verwendung von Kanalnetzcharakteristiken zur Ableitung von optimierten punkt-basierten Monitoringsystemen
(INCIDENT)
ID: 402833446 - Deutsche Forschungsgemeinschaft (DFG)
Die Bedeutung der Auswirkungen des Klimawandels und anthropogener Aktivität für die Bildung von DNAPL-Quellzonen
(ReCAp)
ID: 499973567 - Version / Begutachtungsstatus
- publizierte Version / Verlagsversion
- URN Qucosa
- urn:nbn:de:bsz:14-qucosa2-966106
- Veröffentlichungsdatum Qucosa
- 13.06.2025
- Dokumenttyp
- Artikel
- Sprache des Dokumentes
- Englisch
- Lizenz / Rechtehinweis
CC BY 4.0