- AutorIn
- Tjadina-W. Klein German Cancer Research Center (DKFZ), Heidelberg, Germany#National Center for Tumor Diseases (NCT/UCC), Dresden; German Cancer Research Center (DKFZ), Heidelberg; Medizinische Fakultät and University Hospital Carl Gustav Carus, Technische Universität Dresden; Helmholtz- Zentrum Dresden-Rossendorf (HZDR), Germany#Helmholtz Zentrum München, Helmholtz Pioneer Campus, Neuherberg, Germany#Ludwig-Maximilians-Universität München, Medizinische Fakultät, Munich, Germany
- Stella YangStanford University, Department of Otolaryngology, Head and Neck Surgery, Palo Alto, California, United States
- Mahbuba A. TustyStanford University, Department of Otolaryngology, Head and Neck Surgery, Palo Alto, California, United States
- Jayakar V. Nayak
- Michael T. Chang
- Oliver T. Bruns
- Thomas S. Bischof
- Tulio A. Valdez
- Titel
- Development of a shortwave infrared sinuscope for the detection of cerebrospinal fluid leaks
- Zitierfähige Url:
- https://nbn-resolving.org/urn:nbn:de:bsz:14-qucosa2-935244
- Quellenangabe
- Journal of biomedical optics
Erscheinungsjahr: 2023
Jahrgang: 28
Heft: 9
ISSN: 1560-2281
Artikelnummer: 094803 - Abstract (EN)
- Significance Cerebrospinal fluid (CSF) rhinorrhea (leakage of brain fluid from the nose) can be difficult to identify and currently requires invasive procedures, such as intrathecal fluorescein, which requires a lumbar drain placement. Fluorescein is also known to have rare but significant side effects including seizures and death. As the number of endonasal skull base cases increases, the number of CSF leaks has also increased for which an alternative diagnostic method would be highly advantageous to patients. Aim We aim to develop an instrument to identify CSF leaks based on water absorption in the shortwave infrared (SWIR) without the need of intrathecal contrast agents. This device needed to be adapted to the anatomy of the human nasal cavity while maintaining low weight and ergonomic characteristics of current surgical instruments. Approach Absorption spectra of CSF and artificial CSF were obtained to characterize the absorption peaks that could be targeted with SWIR light. Different illumination systems were tested and refined prior to adapting them into a portable endoscope for testing in 3D-printed models and cadavers for feasibility. Results We identified CSF to have an identical absorption profile as water. In our testing, a narrowband laser source at 1480 nm proved superior to using a broad 1450 nm LED. Using a SWIR enabling endoscope set up, we tested the ability to detect artificial CSF in a cadaver model. Conclusions An endoscopic system based on SWIR narrowband imaging can provide an alternative in the future to invasive methods of CSF leak detection.
- Andere Ausgabe
- Link zum Artikel, der zuerst in der Zeitschrift „Journal of biomedical optics” bei SPIE erschienen ist.
DOI: 10.1117/1.JBO.28.9.094803 - Freie Schlagwörter (EN)
- skull base surgery, shortwave infrared, sinuscopy; endoscopy, cerebrospinal fluid leak, NIR-II
- Klassifikation (DDC)
- 530
- 610
- Verlag
- Spie, Bellingham, Wash.
- Förder- / Projektangaben
- Deutsche Forschungsgemeinschaft (DFG)
SFB 1123: Atherosklerose: Mechanismen und Netzwerke neuer therapeutischer Zielstrukturen
ID: 238187445 - Deutsche Forschungsgemeinschaft (DFG)
Emmy Noether Programme - CZI Deep Tissue Imaging (CZI)
ID: DTI-0000000248 - Bundesministerium für Bildung und Forschung (BMBF)
BetterView - Version / Begutachtungsstatus
- publizierte Version / Verlagsversion
- URN Qucosa
- urn:nbn:de:bsz:14-qucosa2-935244
- Veröffentlichungsdatum Qucosa
- 06.11.2024
- Dokumenttyp
- Artikel
- Sprache des Dokumentes
- Englisch
- Lizenz / Rechtehinweis
CC BY 4.0